Accepted by SAE and ASTM, the standard test method to measure diesel fuel lubricity is conducted on the High Frequency Reciprocating Rig (HFRR). With HFRR, a ball is placed on a flat surface and rapidly vibrated back and forth with a stroke distance of one millimeter while 200 grams of weight is applied.
After a proscribed time period, the flat spot in the ball is measured, establishing the extent to which the additive has reduced wear rates
HFRR PRI-D TEST RESULTS (Download File)
http://www.infomarine.gr/downloads/bunkers/PRI-D-LUBRICITY-TEST-DATA.pdf
Ralph Lewis looks at the issues surrounding low sulphur fuels and lubricity
Ralph Lewis is the Vice President of Houston-based Power Research Inc. Lubricity and stability test data is available on the PRI Internet site.
Contact: Ralph Lewis Power Research Inc. Tel: +1 713 490 1100 Email:
This e-mail address is being protected from spambots. You need JavaScript enabled to view it
Web: www.priproducts.com 
|